Horizontal configurations, the general purpose mini-float level switches provide reliable liquid level detection of clean water and chemical solutions with a 15VA or 30VA reed switch output. Media examples include water and sulfuric acid. The polypropylene or PVDF liquid level sensors are mounted vertically inside the tank or horizontally through the tank wall as a high level alarm or low level alarm. Orientation: +/- 20 degree horizontal. Accuracy: +/- 5mm in water. Repeatability: +/- 2mm in water. Specific gravity: 0.6 minimum. Contact type: (1) SPST reed. Contact rating: 30 VA, 0.5A maximum. Contact output: Selectable NO/NC. Process temperature: F: -40 to 221 degree C: -40 to 105 degree. Pressure: 100 psi (6.9 bar). Sensor rating: NEMA 6 (IP68). Sensor material: Polypropylene. Wire jack material: Polymeric. Wire type: 2-conductor. Wire length: 2’ (61cm). Process mount: 1/2" NPT. Classification: General purpose. Compliance: CE.