The general purpose float leak switch provides reliable leak detection in and around secondary containment sumps and tanks with a 1A relay output. The flat body Valox leak sensor is ideal for placement in hard to reach interstitial areas with limited space. In the event of a leak, the foam polypropylene float will rise to signal the presence of unwanted liquid in the containment vessel. The leak detection switch is typically mounted flat on the bottom of the sump floor or secondary containment tank wall. Orientation: Horizontal. Contact type: (1) SPST reed. Contact state: NC, Open on rise. Contact rating: 30 watts, 240 VAC (0.14 amps resistive), 120 VAC (0.28 amps resistive), 120 VDC (0.07 amps resistive), 24 VDC (0.28 amps resistive). Contact output: NC (opens on rise). Process temperature: F: -40 to 221 degree, C: -40 to 105 degree. Pressure: 50 psi (3.44 bar). Float material: Foamed polypropylene. Body material: Valox 420. Pivot pin: Stainless steel. Wire type: 2 conductor, #22 AWG. Wire length: 10' (3.04m). Wire jacket mat: Halar jacketed. Classification: General purpose. Compliance: CE. Approvals: UL.